Swc4-ld desalination film

您當前位置:貼標機首頁 > Adhesive backing machine > FPC adhesive backing machine

Swc4-ld desalination film

  • 產品名稱:Swc4-ld desalination film
  • 產品分類:Adhesive backing machine
  • 瀏覽次數:177990次
  • 更新時間:2019/8/1 17:18:08
  • 咨詢熱線:133-6065-4218

SWC seawater desalination film has outstanding water production capacity and desalination rate in the industry, combining with optimized water volume, anti-pollution and low energy consumption technologies to meet different needs of customers.

SWC seawater desalination membrane can not only be used for desalination system with seawater as water source, but also for the treatment of industrial wastewater with high TDS. In the selection and design of membrane elements, traditional or mixed installation can be adopted.

SWC4 is the product with the highest desalination rate in the seawater desalination film series of Hyde energy company, which is used to treat seawater with different salt content and low water yield TDS. SWC4 has high desalination and boron removal rates and is suitable for desalination applications with high salt content and high water temperature. SWC4 diaphragm can be rolled into two membrane elements, LD and MAX.

I. performance parameters of swc4-ld Hyde energy desalination membrane:

model

SWC4-LD

specifications

8 inches

performance

Desalination rate

nominal

99.8%

The minimum

99.7%

Water rate

6500gpd (24.6m3/d)

type

Film material

Aromatic polyamide composites

structure

Roll type

Effective membrane area

440ft2(37.2㎡)

Test condition

solution

32000mg/L NaCl

pressure

800psi(5.5Pa)

The temperature

77°F(25℃)

The recovery rate of

10%

pH

6.5-7.0

* the performance parameters are obtained after the system runs steadily for 30 minutes. The actual test conditions may not be exactly the same as the above data, in which case the performance parameters are standardized data based on standard conditions. The deviation of water yield is within ±15 %.

Ii. Use and restriction of products:

Maximum operating pressure

1200 psig (8.27MPa)

The largest water residual chlorine concentration

<0.1 mg/L

Maximum inlet temperature

113 °F (45 °C)

Operating pH range

2-11

Cleaning PH range

1-13

Maximum inlet turbidity

1.0 NTU

The largest water SDI15

5.0

Maximum inflow

85gpm (19.3mm3/h)

Maximum pressure drop for single membrane elements

15psi (0.10 MPa)

This is only a general constraint. For specific projects, more conservative operating parameters can ensure better performance and longer service life. For details, please refer to the relevant technical data of Hyde energy.

Iii. Product description:

Disclaimer: the information and data provided herein are in good faith and in lieu of any warranty. All warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are hereby denied and excluded. The conditions and methods of use of our products are beyond our control. Hyde energy shall not be liable for the results or damages resulting from the use of this information and data. It is the responsibility of the user to determine the suitability of heidner's products for their particular use.